GT AZFScreen Plus v2

SKU: GT-11304 Categories: ,

GT AZFScreen Plus v2 kits has more markers to detect Y chromosome microdeletions, 47 XXY trisomy and Klinefelter syndrome by having several X-chromosome STR, segmental duplication, sex-typing markers.

GT AZFScreen Plus v2

GT AZFScreen Plus v2

The GT AZFScreen Plus v2 kit is an updated AZF kit to comply with the EAA/EMQA 2023 Best Practice Guideline. It is intended for the detection of Y chromosome microdeletions and Klinefelter Syndrome, the two most frequent genetic causes of infertility in men. This kit includes 36 markers (26 STS markers, 3 SD [Segmental Duplication] and 7 STR [Short Tandem Repeat]). Primer designing followed European Molecular Genetics Quality Network guidelines.

Infertility is regarded as a critical problem for most couples. It affects 15-20 % of the reproductive-aged couples worldwide. Male infertility contributes to about 20-30 % of these cases, out of which Y chromosome microdeletions cause 5-10 %. About 3 % of infertile men and 14 % of non-obstructive azoospermia men are affected by Klinefelter Syndrome.

The GT AZFScreen plus v2 kit having 7 X chromosome-  specific STR markers as well as 3 segmental duplications  can detect Klinefelter Syndrome (47, XXY) and other X or Y chromosome aneuploidies (e.g., 47, XXX, 48, XXXY, 48, XXYY, 48, XXXX, etc., though only those related to infertility is of our concern). The GT AZFScreen Plus v2 kit performance has been validated with extensive testing using Applied Biosystems™ 3500/xL and 3130/xl platforms for detection and analysis on more than 200 samples, either as normal, with Klinefelter Syndrome, deletions of AZFa, AZFb, and AZFc or any combination of these deletions on Y chromosome as well as other X chromosome aneuploidies. Please consult the GT AZFScreen Plus v2 user manual for more information.

GT AZFScreen Plus v2 Premium Features

  • ·For rapid and accurate detection of deletions in any of AZF-related regions on the human Y chromosome as well as markers for accurate Klinefelter Syndrome detection
  • Multiplex analysis of 36 markers in a single reaction which makes it less expensive and less of lab work
  • Applicable to a variety of DNA sources, including extracted DNA or using our DNA extraction-free materials such as blood on filter paper like GT DBC, GT DBC Blue, and lysis buffer like GT BLB
  • Easy to use mix and rapid PCR to result
  • Easy to interpret results
  • For research use only. Not for use in diagnostic procedures.

For research use only. Not for use in diagnostic procedures.

Markers

sY153 (AZFb), sY1191 (AZFb), DXDMDSU1.6, sY127 (AZFb), sY157 (AZFc), sY625 (AZFa), sY1224 (AZFb), DXS10101, sY105 (AZFb), sY1192 (AZFb), Y/X b, sY90 (internal control), sY121 (AZFb), sY160 (Heterochromatin), sY1064 (AZFa), M259 (AZFa), SRY(SY14), sY130 (AZFb), AMXY, sY86 (AZFa), ZFY/X, sY84 (AZFa), 11/X, sY82 (AZFa), sY1065 (AZFa), sY254 (AZFc), sY134 (AZFb), DXS8377, sY255 (AZFc), DXS7132, sY131 (AZFb), DXDMDSD13.3, sY1182 (AZFa), DXS981, sY88 (AZFa), DXS6809

AZFScreen Plus kits has more markers to detect AZF and 47 XXY trisomy or Klinefelter syndrome by having several X-chromosome STR, segmental duplication, sex-typing markers.

Chromosome Locations

Table below shows markers in the GT AZFScreen Plus v2 Kit. Names, dye used, size range and chromosome locations are shown.

The GT AZFScreen Plus v2 kit table shows markers locations, chromosomes, and size range. The kit has markers to detect Y chromosome microdeletion or the AZF region and 47, XXY trisomy or Klinefelter syndrome by having several X-chromosome STR, segmental duplications, and sex-typing markers.

The figure shows the locations of X chromosome-specific markers on the X chromosome for the GT AZFScreen Plus v2 kit.
The figure shows the locations of Y chromosome-specific markers on the Y chromosome for the AZFScreen Plus v2 kit.

Sample Profile

Quality Control DNA (GT QCDM102)Download
AZF Microdeletions Sample-1Download
AZF Microdeletions Sample-2Download
AZF Microdeletions Sample-3Download
Klinefelter Syndrome (XXY)Download

The table shows downloadable files for the GT AZFScreen Plus v2 kit. The files can be downloaded after registering. Click on the login to download to register.

Comparison Table

The table compares Genetek Biopharma’s GT AZFScreen v2 kits for the detection of deletion in the AZF region of the Y-chromosome in male infertility as well as the detection of Klinefelter syndrome. The kit is based on EAA/EMQN 2023 Best Practice Guidelines for molecular diagnosis of Y-chromosome microdeletion.

gt-azfscreen-plus-comparison-table AZFScreen kits are for detecting AZF microdeletion. It detects AZFa, AZFb and AZFc. The kit is based on EAA/EMQN best practice guidelines for molecular diagnosis of Y-chromosome microdeletion 2023 recommendation.

Compatibility

This kit is compatible with 5-dyes capillary electrophoresis system such as with Compact Spectrum CE System from Promega or ABI 3130/xl, 3500/xL , and SeqStudio Genetic Analyzers with either 30, 50, or 80 capillaries.

This kit can be used on various sources of DNA including DNA extracted from various sources or DNA obtained using any of extraction free (direct) materials from Genetek such as GT BLB (Blood Lysis Buffer), and filter papers (GT DBC or GT DBC Blue).

Kit Content

The kit contains all the necessary reagents and buffers for multiplex PCR (Multiplex Primer mix, PCR buffer, GT HSTaq DNA Pol in Box A). Also, the kit comes with the GT500 internal size standard as well as GTM5 v2 Matrix Standard for Spectral Calibration of CE systems.

User Manuals

GT AZFScreen Plus v2 User Manual Login to download
GT M5 v2 User Manual Login to download

Quick Protocols

GT AZFScreen v2 Quick Protocol Login to download
GT M5 v2 Quick Protocol Login to download
GT500 Quick Protocol Login to download

Analysis Assistant

GeneMapper ID v.3.2 Login to download
GeneMapper IDX v.1.3 Login to download
GeneMapper IDX v.1.4 Login to download
GeneMapper IDX v.1.5 Login to download
GeneMapper IDX v.1.6 Login to download
GeneMapper v6 Login to download

MSDS (SDS)

PCR Mix Login to download
Primer Mix Login to download
HSTaq Login to download
GT QCDM102 Login to download
PCR Grade Water Login to download
GT500 Size Standard Login to download
GT M5 v2 Matrix Standard Login to download

Brochure / Catalog

GT AZFScreen v2 Brochure Login to download
GT AZFScreen Plus v2 Brochure Login to download

Size SKU. No. Order
50 RXN GT-11304-50 Order Now
100 RXN GT-11304-100 Order Now
1000 RXN GT-11304-1K Order Now
10000 RXN GT-11304-10K Inquire

For further information on mal infertility , tests and AZF please refer to:  EAA/EMQN best practice guidelines for molecular diagnosis of Y-chromosomal microdeletions: State of the art 2023 by C Krausz  et. al., European Molecular Genetics Quality Network.

Related Products